    What size tankless water heater do I need?

    Tankless units are sized by simultaneous flow (GPM) at your required temperature rise, not by gallons of storage. A single shower needs about 2.5 GPM; two showers plus a sink is roughly 6–7 GPM. In northern climates, incoming water near 40°F means a 70–80°F rise, which cuts a unit’s rated GPM roughly in half — so size from the cold-weather rating, not the spec-sheet maximum.

    Run the numbers for your project

    Use the Water Heater Sizing Calculator — Tank & Tankless to get an exact answer for your inputs.

    Open the calculator

    Related questions

    Estimates and general guidance only. Verify against your local code and AHJ before any installation. Gas, electrical, and refrigerant work is hazardous to untrained users.