Find and repair a water heater leak at the T&P valve, drain valve, or fittings, and learn when a leaking tank means the heater must be replaced instead.
Safety
Read before starting
Turn off power/gas and water; beware hot water; depressurize before disassembly.
Pre-Check
3 items · complete before you start0 / 25 complete
Steps
Secure & Inspect
- Turn OFF power/gas
- Close cold inlet
- Dry surfaces; observe fresh water to locate source
✅Continue Gate:Leak source identified (top, side, bottom)?
Top Leaks (connections)
- Tighten/repair hot/cold connections first while supporting opposing fittings
- If corrosion is present, drain to below connection level and disconnect hot/cold connectors
- Remove and replace corroded nipples or dielectric unions with compatible parts
- Apply thread sealant as required for fitting type, reconnect lines, and verify alignment before final tightening
Drain Valve Leaks
- Attempt to reseat by closing firmly
- Turn OFF power/gas and cold inlet; attach hose and drain tank to below valve level
- Remove leaking drain valve and install matching replacement with thread sealant on male threads
- Close valve, refill tank, purge air through a hot faucet, then restore utilities
- Check valve and nearby fittings for active drips under full pressure
✅Continue Gate:Valve replaced/resealed successfully?
T&P Valve Leaks
- Test T&P briefly; if it continues to leak, turn OFF power/gas and cold inlet
- Drain tank below T&P opening, remove discharge tube, and remove old valve
- Install matching T&P replacement with thread sealant on male threads only, then reconnect discharge tube to code-compliant termination
- Refill tank, purge air, restore utilities, and verify no drip after heating cycle
- Verify thermal expansion control (expansion tank)
✅Continue Gate:New T&P installed and no dripping?
Tank Body/Seam Leak
- If water seeping from jacket or base, plan replacement
- Use pan and shut off water to mitigate
✅Continue Gate:Confirmed tank failure?
Restore & Verify
- Open cold inlet; purge air via hot faucet
- Restore power/gas
- Monitor for leaks for 30 minutes